Anderson Connector Size Chart: Complete Guide

Anderson connectors are widely used for connecting batteries, chargers, inverters, electric vehicles, forklifts, solar power systems, and other DC electrical equipment. They are designed to provide secure, low-resistance electrical connections while allowing cables and equipment to be connected or disconnected conveniently.

Choosing the correct Anderson connector requires more than checking its physical size. You also need to consider current capacity, operating voltage, cable size, contact type, housing dimensions, and application requirements. A connector that fits physically may still be unsuitable for the electrical load.

This guide explains common Anderson connector sizes, including SB50, SB120, SB175, SB350, and Powerpole connectors. It also covers dimensions, wire sizes, current ratings, connector types, and practical selection methods.


Anderson Connector Size Chart

Anderson connectors are available in several product families. The SB series is commonly used for higher-current battery and power connections, while the Powerpole series is available in smaller configurations for compact electrical applications.

The following table provides a general overview of common connector sizes.

Connector Model Common Current Class Typical Application Connector Family
PP15 15 A Small DC equipment Powerpole
PP30 30 A Battery and electronic connections Powerpole
PP45 45 A Portable power equipment Powerpole
SB50 50 A class Battery chargers and compact power systems SB
SB120 120 A class Industrial batteries and equipment SB
SB175 175 A class Forklifts and larger battery systems SB
SB350 350 A class Heavy-duty power connections SB

Important: The current classes in this table are common model designations, not guaranteed continuous operating ratings for every contact and cable combination. Actual ratings depend on the selected contacts, conductor size, temperature, installation, and applicable product specifications.

The SB product family includes connectors from SB50 through SB350, with manufacturer specifications covering different current and wire configurations.

Anderson SB Connector Dimensions Chart

The physical dimensions of an Anderson connector are important when selecting a replacement, designing a mounting panel, or checking available installation space.

The following reference dimensions cover several common SB models. Measurements are approximate conversions from published dimensional drawings.

Model Approx. Width Approx. Height Approx. Overall Depth
SB50 36.5 mm 47.6 mm 80.9 mm
SB120 Check model drawing Check model drawing Check model drawing
SB175 55.6 mm 79.4 mm 133.3 mm
SB350 69.8 mm 108 mm 182.6 mm

These values are reference dimensions from a published SB connector drawing. They should not be treated as universal measurements for every housing, contact arrangement, or accessory. For SB120 and other configurations, consult the exact manufacturer’s drawing before designing a mounting space.

SB50 Connector Dimensions

The SB50 is a compact two-pole connector commonly used for battery connections, portable power systems, and electrical equipment.

Its reference dimensions include:

  • Width: approximately 36.5 mm
  • Height: approximately 47.6 mm
  • Overall depth: approximately 80.9 mm

The connector uses replaceable contacts and a genderless housing design. Its compact construction makes it suitable for installations where a larger SB connector would take up unnecessary space.

SB120 Connector Dimensions

The SB120 is designed for higher-current applications than the SB50. It is commonly considered for industrial battery systems, material-handling equipment, and larger DC power connections.

Its housing and contact arrangement are larger than those of the SB50. Exact dimensions depend on the selected housing and accessories, so the manufacturer’s dimensional drawing should be used when checking compatibility.

SB175 Connector Dimensions

The SB175 is a heavy-duty connector used in forklifts, battery-powered machinery, and industrial charging systems.

Published reference dimensions include:

  • Width: approximately 55.6 mm
  • Height: approximately 79.4 mm
  • Overall depth: approximately 133.3 mm

The SB175 is available with different contact configurations. Cable size and contact selection must match the actual application.

SB350 Connector Dimensions

The SB350 is intended for demanding, high-current power applications.

Its approximate reference dimensions are:

  • Width: approximately 69.8 mm
  • Height: approximately 108 mm
  • Overall depth: approximately 182.6 mm

Because of its larger housing and contact arrangement, the SB350 is commonly used in heavy industrial equipment and large battery systems.


Anderson Connector Wire Size Chart

Cable size is one of the most important factors when selecting an Anderson connector. The contact must accept the conductor correctly, and the cable must safely carry the required current.

The following table provides general cable-selection context rather than a universal compatibility specification.

Connector Model Typical Cable Size Range Selection Consideration
PP15 Small-gauge wire Use contacts designed for the selected conductor
PP30 Small to medium-gauge wire Confirm contact and wire compatibility
PP45 Medium-gauge wire Check the exact contact specification
SB50 16–6 AWG for specified contacts Manufacturer specifies different contact options
SB120 Larger conductors Select the correct contact and cable configuration
SB175 Heavy-gauge cable Contact options vary by conductor size
SB350 Very heavy-gauge cable Use the specified high-current contact system

The official SB50 specification lists a wire range of 16 to 6 AWG, approximately 1.3 to 13.3 mm², for specified wire contacts. Other SB models have their own contact and cable requirements.

Understanding AWG and Square Millimeters

Anderson connector contacts may be specified using American Wire Gauge (AWG) or metric conductor cross-sectional area.

AWG Size Approximate Cross-Section
16 AWG 1.31 mm²
14 AWG 2.08 mm²
12 AWG 3.31 mm²
10 AWG 5.26 mm²
8 AWG 8.37 mm²
6 AWG 13.30 mm²
4 AWG 21.15 mm²
2 AWG 33.62 mm²
1/0 AWG 53.49 mm²
2/0 AWG 67.43 mm²

AWG numbers work in reverse: a smaller AWG number represents a thicker conductor. Always check the connector contact’s specified wire range rather than selecting a contact based on the cable’s outside diameter.

Anderson Connector Current Rating Chart

Different Anderson connector models are designed for different electrical loads. However, a connector’s model designation should not be treated as its guaranteed operating current under all conditions.

Connector Model Common Current Class Typical Use
PP15 15 A Small electrical connections
PP30 30 A Portable power equipment
PP45 45 A Battery and DC power connections
SB50 50 A class Compact battery connections
SB120 120 A class Industrial DC equipment
SB175 175 A class Heavy battery connections
SB350 350 A class High-current power systems

The actual allowable current can vary with contact material, conductor size, ambient temperature, duty cycle, connector condition, and ventilation.

For example, the official SB50 specification lists a 120 A UL wire-to-wire rating under specified test conditions, while its UL hot-plug rating is 50 A. This demonstrates why a model name or commonly quoted current class should not replace the complete product specification.

Continuous Current Versus Hot-Plug Current

Continuous current refers to the current a connector can carry under specified operating and thermal conditions.

Hot-plug current refers to the current permitted when making or breaking a connection under defined conditions.

These ratings are not interchangeable. A connector may support a particular current while fully connected but have a lower permitted current when being connected or disconnected.

For safety, do not disconnect a high-current battery connector under load unless the specific product and application are designed for that operation.


Anderson Powerpole Connector Size Chart

Powerpole connectors are modular connectors commonly used in radio equipment, portable power systems, electronics, battery connections, and low-voltage DC applications.

Unlike the larger SB connectors, Powerpole connectors are often selected for smaller conductors and compact installations.

Powerpole Model Common Current Class Typical Application
PP15 15 A Small electronics and accessories
PP30 30 A Portable DC equipment
PP45 45 A Battery connections and power distribution

PP15 Connector

The PP15 is designed for smaller electrical connections. It is useful for compact devices and low-current DC applications where a larger connector would be unnecessary.

PP30 Connector

The PP30 is used for medium-current applications. It provides a modular connection option for portable power equipment and electronic systems.

PP45 Connector

The PP45 is commonly used in battery connections, radio equipment, and DC power distribution. Its contacts and housing must be selected according to the conductor and required electrical load.

Can PP15, PP30, and PP45 Connectors Mate Together?

Powerpole connectors can be configured in modular arrangements, but physical compatibility depends on the housing series, contact arrangement, and assembly configuration.

Do not assume that every connector carrying a Powerpole name will mate with every other Anderson product. Verify the manufacturer’s compatibility information before combining different connector families.


Anderson Connector Types and Their Applications

Anderson connectors are available in several designs for different electrical requirements.

1. SB Series Connectors

The SB series is designed for battery and high-current power connections. Its genderless construction allows compatible connector halves to mate without separate male and female housing designs.

Common applications include:

  • Forklift battery connections
  • Battery chargers
  • Industrial vehicles
  • Electric utility equipment
  • Uninterruptible power supplies
  • Material-handling machinery

SB housings are available in different sizes and colors. Their mechanical keying helps prevent incompatible color-coded housings from mating.

2. Powerpole Series Connectors

Powerpole connectors are modular and commonly used for smaller DC power connections.

They are useful in:

  • Radio communication equipment
  • Portable electronics
  • Battery packs
  • DC distribution panels
  • Testing equipment
  • Small solar power systems

Their modular construction allows compatible housings to be arranged in different configurations.

3. High-Current Connector Configurations

Larger Anderson connectors are used where high current and heavy cable connections are required.

These configurations are found in industrial battery systems, charging equipment, electric vehicles, and heavy machinery.

The correct model depends on the current requirement, cable size, operating environment, and contact configuration.


Anderson Connector Color Code Chart

Many SB connectors are color-coded to help identify voltage configurations and prevent incompatible connections.

The following table shows common recommended voltage color associations.

Housing Color Common Recommended Voltage
Yellow 12 V
Orange 18 V
Red 24 V
Gray 36 V
Blue 48 V
Green 72 V

Color coding is a mechanical identification system, not a voltage-sensing or voltage-regulating feature. A connector does not automatically become safe for a particular voltage simply because its housing has a matching color.

Always confirm the exact connector’s voltage rating and the electrical system’s requirements. Color conventions may also differ in third-party products and custom installations.

Also Read:


How to Measure an Anderson Connector

Measuring an Anderson connector correctly helps identify its size and determine whether it will fit an existing installation.

1. Measure the Housing Width

Use a digital caliper to measure the widest part of the plastic housing. Avoid including protruding accessories unless they are part of the required installation envelope.

2. Measure the Housing Height

Measure the connector from its lowest to highest external point. Keep the caliper square to the housing to avoid inaccurate readings.

3. Measure the Overall Depth

Measure from the front mating surface to the rear of the housing. If a cable clamp or boot is installed, measure the complete assembly separately.

4. Check the Contact Size

Remove the connector from the electrical system and follow the manufacturer’s disassembly procedure. Inspect the contact barrel and identify its specified conductor range.

Never attempt to measure or disassemble an energized connector.

5. Identify the Connector Series

Check the housing markings, contact arrangement, and physical profile. Similar-looking connectors may belong to different series and may not be interchangeable.

Also Read:


How to Choose the Correct Anderson Connector Size

Selecting the correct connector requires checking electrical and mechanical requirements together.

1. Determine the Required Current

Start by identifying the maximum expected operating current. Consider continuous loads, startup current, peak demand, and duty cycle.

Select a connector whose published rating is suitable for the actual operating conditions.

2. Check the Operating Voltage

Confirm that the connector is rated for the system voltage. Do not rely on housing color alone.

Also consider the electrical environment, including switching conditions and possible voltage transients.

3. Match the Cable Size

Choose contacts designed for the cable’s conductor size. A contact that is too small may not accept the conductor correctly, while an incorrectly sized contact may produce a poor crimp.

4. Check the Installation Space

Compare housing width, height, depth, cable exit direction, and accessory clearance.

This is especially important when replacing a connector inside a battery compartment or electrical enclosure.

5. Consider Environmental Conditions

Check whether the connector will be exposed to:

  • Dust and dirt
  • Moisture
  • Oil or chemicals
  • Vibration
  • High or low temperatures
  • Frequent connection cycles

Use suitable protective accessories where the application requires additional environmental protection.

6. Verify Contact and Crimp Compatibility

A connector housing alone does not determine electrical performance. The contact must match the conductor and be installed using the specified crimping method and tooling.

Poor crimping can increase electrical resistance and create dangerous heat.

Also Read:


Anderson Connector Compatibility Guide

Not every Anderson connector is interchangeable with another model.

Compatibility depends on the connector family, housing size, mechanical keying, contact type, and configuration.

Connector Combination Compatibility Guidance
SB50 to SB50 Compatible when matching configurations are used
SB120 to SB120 Compatible when matching configurations are used
SB175 to SB175 Compatible when matching configurations are used
SB350 to SB350 Compatible when matching configurations are used
SB50 to SB175 Not directly interchangeable
SB120 to SB350 Not directly interchangeable
Powerpole to SB Different connector families; not directly interchangeable

The SB family uses genderless housings, meaning compatible halves can mate regardless of which side is connected to the power source.

However, color and mechanical keying can prevent certain housings from mating. Never modify a connector to defeat its keying system.


Common Anderson Connector Applications

Battery Chargers

Anderson connectors are frequently used to connect battery chargers to battery-powered equipment. Their removable design makes charging connections easier to manage.

Forklifts and Industrial Vehicles

Larger SB connectors are used in electric forklifts, pallet trucks, and material-handling equipment. The connector size and cable contacts must be selected according to the vehicle’s electrical system.

Solar Power Systems

Anderson connectors can be used in suitable low-voltage DC battery and power connections. The selected model must be rated for the system’s voltage, current, and environmental conditions.

Electric Vehicles

Some electric vehicle and utility equipment applications use high-current Anderson connectors for battery and charging connections. The required connector depends on the system design and safety requirements.

Portable Power Equipment

Powerpole connectors are useful in portable DC equipment, communication devices, testing systems, and other applications requiring removable electrical connections.


Common Mistakes When Selecting Anderson Connectors

Choosing a Connector by Appearance Only

Two connectors may look similar but belong to different product families. Check the exact model and contact configuration before purchasing.

Ignoring Cable Size

The connector housing may be suitable while the installed contact is not. Always match the contact to the conductor.

Confusing Model Designation with Current Rating

A model’s number or common current class does not guarantee that it can carry that current in every installation.

Ignoring Temperature and Duty Cycle

High ambient temperatures, continuous loading, and poor ventilation can increase connector temperature. Use the manufacturer’s derating information where applicable.

Using Incorrect Crimping Tools

An improper crimp can damage the contact or create a high-resistance connection. Use the recommended tooling and assembly procedure.

Assuming All Colors Mean the Same Voltage

Color coding is helpful, but it is not a substitute for checking the actual electrical specifications.


Frequently Asked Questions

What is the most common Anderson connector size?

SB50 is a commonly used size for battery and portable DC power connections. However, the best connector depends on current, voltage, cable size, and application requirements.

What is the difference between SB50 and SB175?

SB50 is a smaller connector intended for lower-current applications, while SB175 has a larger housing and contact arrangement for heavier electrical loads.

Are Anderson connectors waterproof?

Standard Anderson SB and Powerpole connectors should not automatically be considered waterproof. Environmental protection depends on the specific connector design, accessories, and installation.

Can I use an SB50 connector for a 12V battery?

An SB50 can be suitable for some 12V battery applications if its current rating, contacts, cable size, and installation conditions meet the requirements.

What wire size does an SB50 connector use?

Specified SB50 wire contacts support 16 to 6 AWG conductors, approximately 1.3 to 13.3 mm². The correct contact must be selected for the actual wire size.

Are Anderson connectors genderless?

The SB series uses genderless housings. Compatible halves can mate with each other without separate male and female housing designs.

Can Anderson connectors handle high current?

Yes. The SB family includes models intended for high-current applications. Actual capacity depends on the model, contacts, wire size, temperature, and operating conditions.

How do I identify an Anderson connector?

Check its housing markings, physical dimensions, color, contact arrangement, and product series. Compare these details with the manufacturer’s product drawings.

Can I connect different SB connector sizes together?

Different SB sizes are not directly interchangeable. Use matching connector families and compatible housings.


Conclusion

Choosing the correct Anderson connector size is essential for creating a reliable and safe electrical connection. SB50, SB120, SB175, and SB350 connectors serve different power requirements, while PP15, PP30, and PP45 connectors are commonly used for smaller modular DC connections.

Before selecting a connector, check its physical dimensions, current rating, operating voltage, cable compatibility, contact type, and environmental requirements. Always use the manufacturer’s specifications and dimensional drawings for final selection, especially in high-current battery and industrial applications.